Illustration of a Maryland landlord inspecting a smoke and carbon monoxide detector in a rental unit

Smoke and CO Alarms in Maryland Rentals: What Landlords Need to Check

October 21, 2026•3 min read

A landlord in Mechanicsville passed a routine inspection a year and a half ago and has not thought about smoke alarms since. Then a tenant calls about an alarm that chirps all night. The landlord swaps the battery and moves on, but Maryland's alarm rules ask for more than that.

What Maryland Requires for Smoke Alarms

Maryland changed its smoke alarm rules for rentals in 2018. Battery-only alarms must now have a sealed 10-year battery with a hush feature. Every smoke alarm must be replaced 10 years after the date it was made. If a unit has hardwired alarms, they must be replaced with hardwired alarms. Alarms are needed on every level of the home and in every bedroom.

What Maryland Requires for Carbon Monoxide Alarms

Maryland rental units need a carbon monoxide alarm outside each sleeping area and on every level, including the basement. The alarm can be hardwired with a battery backup, a sealed tamper-resistant 10-year battery model, or a monitored system. A combination smoke and carbon monoxide alarm is allowed.

Check Your Units Now

Start with the date printed on the back of each alarm. If it is more than 10 years old, replace it. Then look at the power source. A battery-only alarm needs the sealed 10-year battery and a hush button. A hardwired alarm gets replaced with another hardwired alarm. Next, count the levels and bedrooms in each unit and make sure every one is covered. Last, write down the install date and test date for each alarm and keep that record with the lease.

What This Looks Like in Southern Maryland

State law sets the minimum, and counties can be stricter. If you own rentals in Charles, St. Mary's or Calvert County, ask your local fire marshal or rental licensing office whether anything extra applies before you buy new alarms.

How This Can Play Out

A landlord in Charlotte Hall owns a three-unit building. Every unit has a battery-only alarm bought years ago, and none has a carbon monoxide alarm outside the bedrooms. Nothing has gone wrong, so it feels fine. It is not fine. The fix is simple: check the dates, switch to sealed 10-year alarms, and add carbon monoxide protection on every level. Doing it on your own schedule is far better than doing it after a problem.

Common Questions

Do I need carbon monoxide alarms in every rental? Maryland law calls for them outside each sleeping area and on every level of a rental unit. Check your county for anything stricter.

Can I use one alarm for both smoke and carbon monoxide? Yes. Maryland allows combination alarms.

Who tests the alarms and replaces batteries? What we found does not split this job between landlord and tenant. Put it in writing in your lease, and a sealed 10-year battery takes most of the battery problem off the table.

What is the fine? We did not find a set fine in the state alarm law. The bigger risk is a tenant getting hurt in a unit that was not protected.

Check This Before Someone Else Does

Not sure your units meet the rules? It starts with a conversation. We walk through what Maryland requires so you know what to check and what to put in your lease. Start here: https://rental911.net/coaching

This is general information, not legal advice. Laws change, so confirm current rules with your county or a Maryland attorney.

blog author avatar

Christine Pollard

Experienced Realtor focusing on all things distressed in Southern Maryland. Most of the time, you will find her working hard for homeowners & would-be homeowners in Charles Cty, Waldorf communities.

Back to Blog

Christine Pollard, Licensed REALTOR®